Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 
RSS

Blog posts tagged with 'acetonitrile'

UK Supplier Formic Acid CAS 64-18-6 | Greyhound Chromatography

Biosolve Formic Acid CAS 64-18-6

Biosolve Bottles

Biosolve products are manufactured under strict and detailed operating procedures. The manufacturing plants meet the latest environmental and quality ISO standards. High purity and high UV-transmission formic acid. The ULC/MS grade formic acid from Biosolve ensures reproducibility and offers the best protection for your columns and detectors. 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles 

BRAND: BIOSOLVE
PART NUMBER: BIO-06914143-1
CAS # 64-18-6
PACK SIZE: 1 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w 

Biosolve Bottles 

BRAND:BIOSOLVE
PART NUMBER:BIO-06914143
CAS # 64-18-6
PACK SIZE: 6 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8-1
CAS # 64-18-6
PACK SIZE: 1 x 25mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8
CAS # 64-18-6
PACK SIZE: 6 x 25mL
 
BUY HERE
 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Buy Formic Acid CAS 64-18-6 | Greyhound Chromatography

Biosolve Formic Acid CAS 64-18-6

Biosolve Bottles

Biosolve products are manufactured under strict and detailed operating procedures. The manufacturing plants meet the latest environmental and quality ISO standards. High purity and high UV-transmission formic acid. The ULC/MS grade formic acid from Biosolve ensures reproducibility and offers the best protection for your columns and detectors. 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles 

BRAND: BIOSOLVE
PART NUMBER: BIO-06914143-1
CAS # 64-18-6
PACK SIZE: 1 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w 

Biosolve Bottles 

BRAND:BIOSOLVE
PART NUMBER:BIO-06914143
CAS # 64-18-6
PACK SIZE: 6 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8-1
CAS # 64-18-6
PACK SIZE: 1 x 25mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8
CAS # 64-18-6
PACK SIZE: 6 x 25mL
 
BUY HERE
 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Formic Acid Suppliers CAS 64-18-6 | Biosolve |Greyhound Chromatography

Biosolve Formic Acid CAS 64-18-6

Biosolve Bottles

Biosolve products are manufactured under strict and detailed operating procedures. The manufacturing plants meet the latest environmental and quality ISO standards. High purity and high UV-transmission formic acid. The ULC/MS grade formic acid from Biosolve ensures reproducibility and offers the best protection for your columns and detectors. 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles 

BRAND: BIOSOLVE
PART NUMBER: BIO-06914143-1
CAS # 64-18-6
PACK SIZE: 1 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w 

Biosolve Bottles 

BRAND:BIOSOLVE
PART NUMBER:BIO-06914143
CAS # 64-18-6
PACK SIZE: 6 x 100mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8-1
CAS # 64-18-6
PACK SIZE: 1 x 25mL
 

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Biosolve Bottles

BRAND: BIOSOLVE
PART NUMBER: BIO-069141A8
CAS # 64-18-6
PACK SIZE: 6 x 25mL
 
BUY HERE
 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Price of Acetonitrile Increased During The Pandemic | Greyhound Chromatography

Acetonitrile Prices Increased During The Pandemic 

During the Coronavirus Pandemic there is a worldwide shortage of Acetonitrile as manufucturing slows down all across the globe.  China and the USA have greatly reduced their manufacturing across all industries as the world tries to combat the Covid-19 virus.  Anything that affects manufucatruring and mass production subsequently affects the production of Aceonitrile. 

While we are experiencing daily increases in the price of solvents it is important that laboratories, both in Research Labs and manufacturing plants monitor their solvent usage and try as best they can to anticipate their solvent usage.  Greyhound Chromatography is using their UK warehouse to stock solvents at today's prices and is organising call off orders with its stakeholders. 

If you have a need for solvents, whether you are a new customer or existing customer with an established call off arrangement now is the time to discuss with Greyhound's Sales Team how your supply chain can be protected. 

Why is Acetonitrile Used in HPLC?

Acetonitrile together with Methanol are the most commonly used solvents for HPLC and UHPLC Chromatography processes because most substances are easily soluble in both solvents, but not saturated hydrocarbons.  Acetonitrile has a low wavelength which means that the solvent will elute first from the column, therefore pressure is reduced on the column.  Lower pressure in the column will have the long term effect of prolonging the life of the column, pressure within the column varies depending on the solvent used and the mixture ratio between the solvent and the sample.  An Acetonitrile based solution generally has a higher elution strength against the same strength solution using Methanol. Some scientists report that the same retention times can be achieved using acetonitrile with less than half the ratio of methanol.  Operator errors can have a significant impact of reproduceable results.  

 

Acetonitrile produces less pressure than Methanol, however the choice between using Acetonitrile against Methanol should not be made on price, (Acetonitrile is generally more expensive than Methanol), choice should be made on performance for your particular instrument and the effect of the chromatography process on the durability of the column.  High grade Acetonitrile has a lower absorbance in routine HPLC and UHPLC procedures and causes less interference than other solvents that can be used.

Biosolve Solvents in Laboratory Glassware

Biosolve solvents, including Acetonitrile, supplied by Greyhound Chromatography, are filtered at 0.1µm and are packed under inert nitrogen gas for longer shelf life, with very low amounts of inorganic metallic contaminants.  Acetonitrile is bottled in pure glass containers to minimise leaching and degradation of the solvent.  Acetonitrile is a clear colourless liquid with an acidity as low as 0-0.001% depending on the grade.  The presence of acid in the solvent improves the chromatographic peak shape.  Full certificates of analysis are available to view before selecting the right grade of solvent for your application.   Acetonitrile Surpa-gradient grade, available from Biosolve, is the highest-grade Acetonitrile solvent available for HPLC and UHPLC in today's worldwide market. 

                                                                                                   Biosolve HPLC Sovents Brochure                                               Biosolve Logo

 

Acetonitrile is shipped under Dangerous Goods regulations as it is a highly flammable liquid and vapour.  Safety procedures should be closely followed for the safe handling of Acetonitrile, including keeping away from sparks and open flames, hot surfaces and heated storage rooms.  When handling take reasonable precautions to ensure that it does not go on skin or near eyes.  If Acetonitrile does come into contact with clothes, remove the clothing and rinse thoroughly in water.  If it comes into contact with the skin, wash cautiously with water.  If acetonitrile comes into contact with the eyes, remove contact lenses if they are present, rinse with water for several minutes and seek medical advice. 

 

Bioslve Vials Image

Is there a need to wash columns frequently during HPLC

It is important to look after your columns to prolong their life and also their integrity.  Washing a column is an important process that should be done regularly.  Depending on how many samples you are processing and how often you are using them will determine how many times you wash the column.  Storage of the cleaned columns should also be considered.  It is important to establish a wash cycle in the laboratory, if you do not you will notice a gradual pressure build up and you may experience ghost peaks after the first injection.   Ghost peaks are caused by compounds eluting off the column in later runs despite being injected in a previous analysis. 

This is the recommendation for a column that is to be stored over a long period.  Replace buffers and modifiers at the end of the day, it is recommended that you wash the column with 70% water, 15% methanol and 15% acetonitrile.  divert the eluent from the column to waste so as not to contaminate the detectors.  Wash the column in 100% methanol and 100% acetonitrile, both for at least 15 minutes.  Store the column subject to the manufacturers recommendations, this will preserve the column, which may last for years depending on the number of samples processed and the care you give to your column.   For daily use, wash the column in 70% water, without using an acid or modifier, and store overnight subject to manufacturer's instructions. 

 

Bioslve Vials Image

About Solvents 

Solvents are liquids which dissolve other substances with water a common example. The selection of a solvent will depend on whether or not something dissolves in it (solvency), its evaporation rate, boiling point, viscosity, surface tension and many other factors.

Acetonitrile together with Methanol are the most commonly used solvents for HPLC and UHPLC Chromatography processes because most substances are easily soluble in both solvents, but not saturated hydrocarbons.  Acetonitrile has a low wavelength which means that the solvent will elute first from the column, therefore pressure is reduced on the column.  Lower pressure in the column will have the long term effect of prolonging the life of the column, pressure within the column varies depending on the solvent used and the mixture ratio between the solvent and the sample.  

Isopropanol (IPA) is used as a solvent in cosmetics and personal care products, de-icers, paints and resins, pharmaceuticals, food, inks and adhesives. A pharmaceutical grade of IPA is used in products such as medicinal tablets as well as disinfectants, sterilisers and skin creams. IPA is used in de-icers and cleaning products because it stays in liquid form well below the freezing point of water.

Acetone is a widely used solvent. Pharmaceuticals is the largest consumer of acetone solvent with significant quantities also being used in glass reinforced plastics, cigarette tow, rubber chemicals and household, cosmetic and personal care products.

Ethyl acetate has applications as a solvent in inks for flexographic and rotogravure printing. It is used as an extraction solvent in the production of pharmaceuticals and food, and as a carrier solvent for herbicides.

All of the above solvents are seeing dramatic price increases in 2020 as demand grows worldwide for products that are used to combat the effects of Covid-19.  Many manufacturers are switching production from their regular products to producing hand and surface sanitizers that are in high demand worldwide.  The price of these products has more than trebled since the start of 2020.  Many alcohol manufacturers have ceased production of commercial alcohol products because of the closure of bars and restaurants and are now producing sanitizers either comercially or as a product they can donate to the health service to assist the fight against Covid-19.    

 

Historic World Shortage of Acetonitrile

In 2008 there was a world shortage of Acetonitrile, (a by-product from the manufacture of acrylonitrile) because of several factors, including, Chinese manufacture being shut down because China was hosting the Olympics and all industry within China was either closed down or drastically reduced in an attempt to improve the standard of air during the Olympics.  Also, during Hurricane Ike in the USA an Acetonitrile factory was damaged in Texas causing further shortages.  As Methanol is an acceptable substitute in most HPLC methods the shortage can be overcome.  Acetonitrile is seen as a valuable commodity due to the volume used worldwide for a variety of purposes other than Laboratory analysis.  The 2020 Coronavirus Pandemic is again causing shortages worldwide. 

 

Author:

Susan Massie, Sales & Marketing Director

Greyhound Chromatography and Allied Chemicals

www.greyhoundchrom.com

 

Scan for Biosolve Products. 

Biosolve Solvents QR Code   Biosolve Catalogue Image

 New Q-Fil Syringe Filters Catalogue

 Q-Fil Syringe filters Catalogue Cover Image

  

CONTACT US   

 

Tel:        +44 (0) 151 649 4000   

 

Web:     www.greyhoundchrom.com   

 

Email:   marketing@greyhoundchrom.com   

 

FOLLOW US   

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

 

SIGN UP HERE   

 

Greyhound Monthly Newsletter   

 

CATALOGUE DOWNLOADS   

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

 

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

 

                Wellington Perfluoroalkyl Compounds

 

Dandy Vice Brochure  Chem Service Catalogue  

 

 

 

 

 

 

 

Formic Acid CAS 64-18-6 99%, ULC/MS Grade 99.0% | Biosolve Solvents | Greyhound Chromatography

Formic Acid CAS # 64-18-6; Synonym: Methanoic acid, Formylic acid

Formic Acid 99%, ULC/MS Grade 99.0% w/w

Highest quality for very demanding work of chromatography, analysed for very high HPLC, UHPLC, SFC and MS performances, coupled with very low amounts of inorganic metallic contaminants.

Shipping: UN 1779; Hazard Class 8; Packing Group II

For alternative pack sizes, bulk quantities and call off orders please contact our sales department for a quotation

Many other High Grade Solvents available - Email your requirements to sales@greyhoundchrom.com

 

Biosolve's Range of UHPLC/HPLC Solvents

Chromatography    Trace Analysis    Life Sciences

Karl Fischer    NucleoSyn    Peptide Synthesis

Solvents & Chemicals    Electronic Guide    Bulk

 

 Greyhound Vials Catalogue Image

 

Ordering Information:

 

You can order on-line (registration required), www.greyhoundchrom.com 

 

 or by telephone, +44 (0)151 649 4000 - Sales Department

 

 Request a quotation: sales@greyhoundchrom.com

 

 General Information: info@greyhoundchrom.com

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

 

 

CATALOGUE DOWNLOADS

Biosolve Catalogue 2015 - 2017       Biosolve Headspace Catalogue

 

Methanoic Acid Cas 64-18-6 | Biosolve Solvents | Greyhound Chromatography

Methanoic Acid

Formic Acid 99%, ULC/MS Grade 99.0% w/w.   CAS # 64-18-6; Synonym: Methanoic acid, Formylic acid

Highest quality for very demanding work of chromatography, analysed for very high HPLC, UHPLC, SFC and MS performances, coupled with very low amounts of inorganic metallic contaminants.

Shipping: UN 1779; Hazard Class 8; Packing Group II

For alternative pack sizes, bulk quantities and call off orders please contact our sales department for a quotation

 

 

 

 

Chromatography    Trace Analysis    Life Sciences

Karl Fischer    NucleoSyn    Peptide Synthesis

Solvents & Chemicals    Electronic Guide    Bulk

 

 Greyhound Vials Catalogue Image

 

Ordering Information:

 

You can order on-line (registration required), www.greyhoundchrom.com 

 

 or by telephone, +44 (0)151 649 4000 - Sales Department

 

 Request a quotation: sales@greyhoundchrom.com

 

 General Information: info@greyhoundchrom.com

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

 

CATALOGUE DOWNLOADS

Biosolve Catalogue 2015 - 2017       Biosolve Headspace Catalogue

Honeywell Research Chemicals | Greyhound Chromatography

Greyhound Chromatography Honeywell Authorised Distributor

 

Pursuing excellence

for more than 200 years

Honeywell's story began more than 200 years ago when German chemist Johann Daniel Riedel successfully manufactured pharmaceutical products. While the world has changed greatly since then, Honeywell remains committed to providing the highest quality chemicals through innovative and cutting-edge manufacturing processes. Explore Honeywell's diverse product line to discover how Greyhound Chromatography can help your lab. 

 

PRODUCT LISTING

 

Honeywell Research Chemicals

Honeywell Supporting Covid 19 Research

Honeywell Pharma and Bio Pharma solutions

Honeywell Application focussed Solutions

Honeywell Enabling Covid 19 Research

 

  

Hydranal Karl Fisher TitrationLeading the way in innovation and safety since 1979, Hydranal™ reagents for Karl Fischer titration have been recognized as the most trusted brand in the industry.  

Honeywell Water Determination in Crude Oil  Honeywell Insulating Oil  Honeywell Nitrogen Bases  Honeywell Determinitation in Dimethyl Sulfoxide
 Honeywell Water Determinitation in Aldehydes and Ketones  Honeywell Hydranal Manual  Honeywell Karl Fisher Titration with Hydranal-Methanol Rapid  Honeywell High confidence. Accurate Results

Karl Fisher Banner Heading

 

Best practice in Karl Fischer Titration

 

Honeywell Karl Fischer Titration Guide

Chromasolv Solvents

With more than 100 dedicated solvents and blends, Chromasolv™ solvents offer better impurity profiles and higher lot-to-lot consistency. 

 

Chromasolv High Purity Solvents  Chromasolv Head to Head comparison  Chromasolv Residual Solvents Analysis

 Fluka Analytical Standards

Be confident and advance your research with Honeywell's Fluka™ Analytical Standards.

Honeywell's standards come complete with printed COA and free expert technical support. 

Fluka Analytical Standards

STANDARDS OVERVIEW

SAMPLE CoFA

PRODUCT LIST

Honeywell Quality Assured

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

You may also be interested in 

An Overview of Honeywell's Research Chemicals 

Honeywell Powerpoint Presentation

Honeywell Reference Materials Presentation

Honeywell Analytical Reference Standards

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds