Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 

ZPure Hydrocarbon Stainless Steel Filters | Greyhound Chromatography

ZPure Hydrocarbon Stainless Steel Filters

ZPure Hydrocarbon Filters

ZPure Hydrocarbon Filters (2)

Also Available:

Z-Pure™ Gas Purifiers and Filters

    Gas Purifiers & Filters 2022 Catalogue Cover Image                    Advanced Filter System Image

  PDF DOWNLOAD                 ADVANCED FILTER SYSTEM

AFS Gas Purifiers and Filters - Advanced Filter System 

The high-capacity gas purifying system that removes contaminants from inert gases and hydrogen. The AFS Purifiers can be expected to supply multiple GC Installations for an extended period of time depending on the laboratory environment.

The two part system includes a small stainless steel manifold and a high capacity purifier cartridge. The manifold mounts to a laboratory wall or bench with brackets included in the installation kit and connects to the gas lines with stainless steel compression fittings.

The AFS 1 PurifierCartridge removes oxygen, moisture and hydrocarbons (greater than C4) from inert gases and hydrogen.   It contains a high sensitivity oxygen and moisture indicator.  When the cartridge is depleted, the oxygen indicator changes from GREEN to GREYand the moisture indicator changes from BLUE to BROWN.

PolyGas AFS Purifier I Cartridge is a high capacity Non-Hazardous purifying system that removes oxygen, moisture and hydrocarbons (greater than C4) from inert gases and hydrogen.  It contains a high sensitivity oxygen and moisture indicator.  When the cartridge is depleted, the oxygen indicator changes from GREEN to GREY and the moisture indicator changes from BLUE to BROWN. 

The AFS II Purifier Cartridge removes moisture and hydrocarbons (greater than C4) from air, inert gases and hydrogen.  It contains a high sensitivity moisture indicator.  When the cartridge is depleted, the moisture indicator changes from BLUE to BROWN. 

The AFS III Purifier Cartridge removes moisture from inert gases and hydrogen.  It contains a high sensitivity moisture indicator.  When the cartridge is depleted, the moisture indicator changes from BLUE to BROWN.

 

Advanced Filter System Image  AFC Complete Kit Image  AFC Manifold Unit

           ADVANCED FILTER SYSTEM                         AFC  COMPLETE KIT                     AFC MANIFOLD UNIT

Advanced Filter Systems Product Details

 

ALSO AVAILABLE

ZPure™ LS H2O Filters for use with ASTM D6550 and ASTM D5186 using SFC

ZPure™ LS H20 Filter Image

The H2O filter for use with ASTM D6550 and ASTM D5186 using SFC

The ZPure H2O Filter removes moisture from inert gases, He, Ar, N2, H2, methane and clean dry air (CDA) to low ppb levels, with very high capacity. It is recommended for any application that requires ultra-dry gas, and is available in 130cc and 475cc stainless steel cylinders with standard 1/4” and 1/8” brass and stainless steel compression fittings.

ASTM D6550 and ASTM D5186 using Supercritical Fluid Chromatography has been approved as an alternative to FIA ASTM D1319 standard test method for Hydrocarbon Types in Liquid Petroleum Products. This filter was manufactured with molecular sieve 3A by customer request for use with a Supercritical Fluid Chromatograph.

Moisture Removal for Specialized Applications

  •  CO2 purification for SFC - In the petroleum industry, both the Environmental Protection Agency (EPA) and California Air Resources Board (CARB) have approved ASTM D6550 and ASTM D5186 for final product release of gasoline and diesel fuels. In this type of application, the reduced heating of 3A is expected to reduce desorption of already bound moisture, protecting sensitive and expensive columns.
  •  Mixed source gas - Purifiers should not be used to remove water from individual gas samples intended for analysis; some proportionation may occur.  Gas purifiers typically use either molecular sieve 5A or 13X adsorbents to remove water from gas streams. These are beneficial for carrier gases used with GC or GC/MS, because in addition to water they also remove many other common contaminants. (“5” and “13” refer to the adsorbent’s pore diameter in angstroms.) In some applications, however, 3A molecular sieve with smaller pore size may be preferred. It removes water yet excludes almost all larger molecules including CO2, the carrier used in Supercritical Fluid Chromatography (SFC). Since CO2 is excluded there is no significant temperature rise on installation, due to heat of adsorption, which may occur with 5A or 13X purifiers.

Green Colour Filter Header Image

ZPure LS H2O Filter, 130cc, 1/8" S/S Compression Fittings, with Molecular Sieve 3A                              

17-203011-B

ZPure LS H2O Filter, 475cc, 1/8" S/S Compression Fittings, with Molecular Sieve 3A

17-203010L-SS

ZPure LS H2O Filter, 475cc, 1/4" Brass Compression Fittings, with Molecular Sieve 3A

17-203011L-B

ZPure LS H2O Filter, 475cc, 1/4" S/S Compression Fittings, with Molecular Sieve 3A

17-203011L-SS

   

 

 Specifications for Filters Header Image 

Specifications for ZPure Filter Image

 Gas Purifiers & Filters 2022 Catalogue Cover Image

      PDF DOWNLOAD

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Leave your comment